文化大學機構典藏 CCUR:Item 987654321/40201
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 46965/50831 (92%)
造访人次 : 12650955      在线人数 : 513
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于CCUR管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://irlib.pccu.edu.tw/handle/987654321/40201


    题名: 划船測功儀對大學男生有氧能力評估之探討
    The Use of Rowing Ergometer to Evaluate the Aerobic Capacity of Male College-Aged Adults
    作者: 鍾雨純
    陳麗玉
    陳竑廷
    吳慧君
    贡献者: 體育學系
    关键词: 攝氧峰值
    最大換氣量
    划船測功儀
    Bruce protocol
    VO₂max
    VEmax
    Rowing ergometer
    日期: 2010-06
    上传时间: 2018-06-07 16:17:35 (UTC+8)
    摘要: The purpose of the study was to evaluate the effectiveness of using rowing ergometer to measure maximum aerobic capacity, as well as to compare the maximum aerobic capacity measured by rowing ergometer and treadmill. The subjects were 18 college-aged adults who engaged in regular exercise (aged 22±1.8yr, height 173.2±3.4 cm, weight 65.6±7.3 kg). The subjected were randomly divided into two groups by using a counterbalanced design. Subjects in group A were tested by using treadmill in the first test and using rowing ergometer in the second test. Subjects in group B were tested in a reversed order. Three days of rest was given between the first and the second test. Bruce protocol was used in the treadmill test, while in the rowing ergometer test, the rowing frequency was set at 30 per min with wind speed level 5, and the starting load was set at 50W and progressively increased by 30W every 3 min. The Mobile wireless metabolic analyzer Meta Max was used to measure the aerobic capacity in both the treadmill and rowing test. Data were analyzed by using paired t-test and the α level was set at .05. The result revealed that the VO(subscript 2max)(9.48±5.45 vs. 44.15±4.33 ml•kg^(-1)•min^(-1), p<.05) and VE(subscript max) (122.17±18.1vs. 105.68±14.72 L•min^(-1), p<.05) obtained from the treadmill test were significantly higher than the rowing ergometer. It was concluded that because of the exercise mode of the treadmill, the aerobic capacity measured by using treadmill is more valid than rowing ergometer. However, because of the relative convenience and low cost of the rowing ergometer, it is suggested that the aerobic capacity measured by treadmill protocol can be used as the criterion variable to develop a regression equation for rowing ergometer.
    關聯: 運動教練科學 18 2010.06[民99.06] 頁27-36
    显示于类别:[體育學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML116检视/开启


    在CCUR中所有的数据项都受到原著作权保护.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈