    題名: Heat and mass transfer of a planar membrane humidifier for proton exchange membrane fuel cell
    作者: Chen, Chen-Yu
    Yan, WM (Yan, Wei-Mon)
    Lai, CN (Lai, Chi-Nan)
    Su, JH (Su, Jian-Hao)
    貢獻者: 機械系
    關鍵詞: Heat and mass transfer
    Planar membrane humidifier
    PEM fuel cell
    Humidifier performance
    日期: 2017-06
    上傳時間: 2017-06-08 09:04:28 (UTC+8)
    摘要: The proton exchange membrane fuel cell (PEMFC) becomes more important as an alternative energy source recently. Maintaining proper water content in the membrane is one of the key requirements for optimizing the PEMFC performance. The planar membrane humidifier has the advantages of simple structure, low cost, low pressure drop, light weight, reliable performance and good gas separability. Thus, it is a common external humidifier for PEMFCs. In this work, a planar membrane humidifier for kW-scale PEMFCs is developed successfully. The heat and mass transfer of humidifier is discussed and its performance is analyzed in term of dew point approach temperature (DPAT), water vapor transfer rate (WVTR) and water recovery ratio (WRR). The DPAT of the humidifier with the counter flow approach reaches about 6 degrees C under inlet dry air of 50 degrees C and 60% RH and inlet humid air of 70 degrees C and 100% RH. The rate of pressure loss of the humidifier is 5.0 x 10(2) Pa/min at the torque of 7 N m, which reaches the standard of commercial planar membrane humidifiers. From the tests, it is found that increasing the air flow rate increases the WVTR. However, the DPAT and the WRR are not improved by increasing the WVTR as the air flow rate is higher than the optimal value. In addition, increasing the inlet temperature or the humidity of dry air decreases the WVTR and the WRR. Nevertheless, the DPAT is improved at elevated inlet temperatures or humidities of dry air. Furthermore, the performance of the humidifier with the counter flow approach is better than that with the parallel flow approach. The DPAT difference between the two flow approaches reaches up to 8 degrees C. (C) 2017 Elsevier Ltd. All rights reserved.
    關聯: INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER 卷: 109 頁碼: 601-608
    顯示於類別:[機械工程系暨機械工程學系數位機電研究所] 期刊論文